Slot-type photoelectric switch SLUR-S3U4 series


Summary:

This product is a sensor device used for detecting the position of the elevator car to determine whether the elevator has reached the specified floor, and its main principle is based on the photoelectric effect.

Classification:

Multi-channel photoelectric switch

Related Documents:

  • Summarize
  • Technical data
  • Related downloads
    • Commodity name: Slot-type photoelectric switch SLUR-S3U4 series

    This product is a sensor device used for detecting the position of the elevator car to determine whether the elevator has reached the specified floor, and its main principle is based on the photoelectric effect.

    Applications

    This product is used for the position detection of elevator cabins to determine whether the elevator is level at the specified floor, and its main principle is based on the photoelectric effect.

     

    Model

    Note: Models SH-GLS126N3, SLUR-126N3.5PDPO, and 126N3.5PDPC are also applicable to this description.

  • Power Supply Voltage

    DC15~35V±5%

    Current Consumption

    54mA

    Detection Distance

    40mm

    Detected Object

    >φ3mm, opaque object

    Detection Channel

    Four Channels

    Light Source Properties

    940mm

    Control Output

    Load Voltage Max: 60V; Single Channel Drive Current: Max: 200mA; Residual Voltage Max: 0.7VDC

    Protection Circuit

    Reverse connection protection for power supply, over-voltage and over-current protection at output terminal

    Response Time

    <1ms

    Ambient Illumination

    Incandescent Lamp: ≤4000Lux; Sunlight: ≤100000Lux, sunlight should not directly shine on the light-receiving surface

    Ambient Temperature

    Operating: -25℃~85℃; Storage: -30℃~100℃

    Ambient Humidity

    Operating: 35~80%RH; Storage: 35~80%RH

    Insulation Resistance

    Min: 20MΩ (500VDC)

    Insulation Withstand Voltage

    500VAC 50/60Hz 1min

    Vibration Resistance

    10~55Hz, amplitude 1.5mm, X, Y, Z directions for 2 hours each

    Shock Resistance

    500m/s², X, Y, Z directions for 3 times each

    Protection Level

    IP40 (IP53, IP65 can be customized)

    Shell Material

    ABS

    Weight

    About 200g

    Cable

    RVV 6*0.2, default 3m

    Note: The standard length of the cable is 3 meters. If other specifications are needed, please specify when ordering.